Inventec logo

Inventec Artemis II Rack

rack
72× GB300
NVLink across all 72 GPUs over passive copper cable cartridges, with nine 1RU NVLink switch trays; scale-out is ConnectX-8 at 800 Gb/s InfiniBand east-west, carried on two I/O boards holding two SuperNICs each, plus a BlueField-3 DPU at 400 Gb/s north-south
Power
136.0
kW Total
Memory
—
GB Total

The Blackwell Ultra generation of Inventec's Artemis rack, built on the NVIDIA GB300 NVL72 and the MGX platform, again pairing 36 Grace CPUs with 72 Blackwell GPUs across eighteen compute trays and nine NVLink switch trays in a 48RU rack. The change from the first Artemis is in the network: east-west moves from ConnectX-7 at 400 Gb/s to ConnectX-8 at 800, carried on two dedicated I/O boards with two SuperNICs apiece, so back-end bandwidth keeps pace with the GPUs. Cooling narrows to row-based and sidecar, with leakage detection, and Inventec rates the rack at a maximum of 136 kW. No throughput or memory figures are published. This entry links to no reference design because the only GB300 NVL72 record in this catalogue is NVIDIA's own DGX appliance, which is a finished competing product rather than a reference platform.

We will point you at suppliers who have it. Free, and no signup.

Systems built on this design

3 configurations

Built on the NVIDIA GB300 NVL72 baseboard, so accelerator performance matches the reference. Chassis, CPU, memory and cooling are this vendor's own.

System Details

GPU Configuration

GPU Count: 72 GPUs
Architecture: Blackwell Ultra
Interconnect: NVLink across all 72 GPUs over passive copper cable cartridges, with nine 1RU NVLink switch trays; scale-out is ConnectX-8 at 800 Gb/s InfiniBand east-west, carried on two I/O boards holding two SuperNICs each, plus a BlueField-3 DPU at 400 Gb/s north-south

System Specifications

Form Factor: rack
Total Power: 136.0 kW
Total Memory: —
Memory Bandwidth: 576 TB/s

Powered by NVIDIA GB300

This system utilizes 72 × NVIDIA GB300 NVL72 GPU 288GB GPUs, each delivering exceptional performance for AI and HPC workloads.

Per GPU TDP

—

Per GPU Memory

288 GB

Process Node

4nm

Architecture

Blackwell Ultra

Documentation & Resources

Flopper Spec Sheet

Inventec Artemis II Rack specifications, generated from our database. Printable.

Vendor product page

Inventec Artemis II Rack documentation

View ↗

Inventec Artemis Rack

Inventec • Latest version

View Document ↗

Typical Use Cases

AI/ML Training
High-Performance Computing
Data Analytics

The Inventec Artemis II Rack runs 72× GB300 GPUs over NVLink across all 72 GPUs over passive copper cable cartridges, with nine 1RU NVLink switch trays; scale-out is ConnectX-8 at 800 Gb/s InfiniBand east-west, carried on two I/O boards holding two SuperNICs each, plus a BlueField-3 DPU at 400 Gb/s north-south.

© 2026 Flopper.io - Compare the hardware powering AI