Inventec Artemis II Rack
The Blackwell Ultra generation of Inventec's Artemis rack, built on the NVIDIA GB300 NVL72 and the MGX platform, again pairing 36 Grace CPUs with 72 Blackwell GPUs across eighteen compute trays and nine NVLink switch trays in a 48RU rack. The change from the first Artemis is in the network: east-west moves from ConnectX-7 at 400 Gb/s to ConnectX-8 at 800, carried on two dedicated I/O boards with two SuperNICs apiece, so back-end bandwidth keeps pace with the GPUs. Cooling narrows to row-based and sidecar, with leakage detection, and Inventec rates the rack at a maximum of 136 kW. No throughput or memory figures are published. This entry links to no reference design because the only GB300 NVL72 record in this catalogue is NVIDIA's own DGX appliance, which is a finished competing product rather than a reference platform.
We will point you at suppliers who have it. Free, and no signup.
System Details
GPU Configuration
System Specifications
Powered by NVIDIA B300
This system utilizes 72 × NVIDIA B300 SXM 288GB GPUs, each delivering exceptional performance for AI and HPC workloads.
Per GPU TDP
1400W
Per GPU Memory
288 GB
Process Node
4nm
Architecture
Blackwell Ultra
Documentation & Resources
Official Datasheet
Inventec Artemis II Rack technical specifications
Inventec Artemis Rack
Inventec • Latest version
Typical Use Cases
The Inventec Artemis II Rack runs 72× B300 GPUs over NVLink across all 72 GPUs over passive copper cable cartridges, with nine 1RU NVLink switch trays; scale-out is ConnectX-8 at 800 Gb/s InfiniBand east-west, carried on two I/O boards holding two SuperNICs each, plus a BlueField-3 DPU at 400 Gb/s north-south.